DIAGNOSTICS
[Armature Delta] P.172
Shows the actual firing angle (in µs).
Display/Drive Units: uSEC
Parameter Type: Output
Group: Diagnostics
Factory Default: 0
Minimum Value: 6480
Maximum Value: 6480
[Cur Compound TP] P.173
An output testpoint that represents the
current compounding value being used by
the drive.
Display/Drive Units: RPM
Parameter Type: N/A
Group: Diagnostics
Factory Default: 0
Minimum Value: 4095
Maximum Value: 4095
[Field Delta] P.174
The firing angle of the output of the field
current regulator to the regulated field supply
gate firing circuit. Output of the field current PI
block.
Display/Drive Units: DEG
Group: Diagnostics
Parameter Type: Read Only
Factory Default: 0
Minimum Value: 5400
Maximum Value: 5400
[Fld Econ Active] P.175
Indicates the present state of field economy
mode.
Display/Drive Units: Numeric/Text
Parameter Range: 0 = Not Active
1 = Active
Parameter Type: Read Only
Group: Diagnostics
Factory Default: 0
Minimum Value: 0
Maximum Value: 1