OUTPUT CONFIG
[Anlg Out 3 Type] — P.152
Only used if the I/O Expansion kit is installed.
Selects the type of signal to be generated by
analog output 3 (terminals 54 and 55 on the
I/O Expansion board). This setting must
match the settings of jumpers J14 and J15 on
the I/O Expansion board.
Display/Drive Units: Numeric/Text
Parameter Range: 0 = 0-10V
1 = ±10V
2 = 4 -20mA
3 = 10–50mA
Default Setting: ±10V
Parameter Type: Configurable
Group: Output Config
Factory Default: 1
Minimum Value: 0
Maximum Value: 3
[Anlg Out 4 Gain] — P.153
Adjusts analog output 4. Only used if I/O
Expansion kit is installed.
Display/Drive Units: VDC
Parameter Type: Tunable
Group: Output Config
Factory Default: 1.000
Minimum Value: 0.500
Maximum Value: 1.300