Instruction Manual

548 Programming Parameters
Publication 1397-5.0 June, 2001
INPUT CONFIG
[Anlg In 2 Zero] P.131
Removes any hardware introduced offset
from the analog reference signal. Typically, it
will be 0.
Display/Drive Units: Numeric
Parameter Range: 200 to + 200
Parameter Type: Tunable
Group: Input Config
Factory Default: 0
Minimum Value: 200
Maximum Value: 200
[Anlg In 3 Gain] P.132
Only used if the I/O Expansion kit is installed.
Scales analog input 3 (Terminals 50 & 51 on
the I/O Exp). Typically 1.000
Display/Drive Units: Numeric
Group: Input Config
Parameter Type Tunable
Factory Default: 1.000
Minimum Value: 0.750
Maximum Value: 2.250
[Anlg In 3 Type] P.133
Only used if the I/O Expansion kit is installed.
Selects the type of signal that the drive will
expect to be connected to analog input 3
(terminals 50 and 51 on the I/O Expansion
board).The value of this parameter must
match the setting of jumpers J11 and J12 on
the I/O Expansion board.
Refer to the I/O Expansion Inputs (Fig. A.2)
block diagram for further information.
Display/Drive Units: Numeric
Parameter Range: 0 = 0-10V
1 = ±10V
2 = 4 -20mA
3 = 10-50mA
Default Setting: ±10V
Group: Input Config
Factory Default: 1
Minimum Value: 0
Maximum Value: 3