FEATURE SELECT
[Trim Mode Type] P. 11 7
Selects the type of trim mode to be used by
the drive:
D No Trim
D Incremental
D Proportional Allows multiple drive
sections with a common reference to
operate and ramp at different values.
Display/Drive Units: Numeric/Text
Parameter Range: 0 = No Trim
1 = Incremental
2 = Proportional
Parameter Type: Tunable
Group: Feature Select
Factory Default: 0
Minimum Value: 0
Maximum Value: 2
Proportional is a type of draw. By using draw, one section can operate 10% faster than an upstream section. When a ramp occurs on the
common reference, the two sections will support the 10% draw throughout the ramp. [S-Curve Rounding] will interfere with the [Accel Time]
and the [Decel Time] so that the draw will not be constant. Therefore, it is recommended that [S-Curve Rounding] be set to 0% if [Trim Mode
Type] is set to Proportional. Incremental trim is not affected by this limitation.
This parameter also affects how the acceleration and deceleration times are interpreted.
[Trim Range] P. 11 8
Uses the selected trim reference signal to
generate draw percentage. Determines how
much the trim signal will affect the drive
reference.
Display/Drive Units: %
Parameter Type: Tunable
Group: Feature Select
Factory Default: 0%
Minimum Value: 0%
Maximum Value: 100%
[Trim Ref Source] P. 11 9
Trim reference source selection. Display/Drive Units: Numeric/Text
Parameter Range: 0 = Register
1 = Anlg In 1
2 = Anlg In 2
3 = Anlg In 3
4 = Anlg In 4
5 = Frequency In
6 = Adapter 1
7 = Adapter 2
8 = Adapter 3
9 = Adapter 4
10 = Adapter 5
11 = Adapter 6
Parameter Type: Tunable
Group: Feature Select
Factory Default: 0
Minimum Value: 0
Maximum Value: 11