Instruction Manual

13Introduction
Publication 1397-5.0 June, 2001
Drive specific data, such as horsepower (or output current),
regenerative or non-regenerative type, line voltage etc. can be
determined by the Drive model number. The model number structure
is shown below.
1397 B005 OPTIONS
1397
B
1397
First Position
Bulletin Number
Second Position
Voltage
Letter
A
230V AC
Voltage
Rating
001
002
003
005
007
010
015
020
025
030
040
050
060
075
100
125
150
HP (kW)
1.5 (1.1)
2 (1.5)
3 (2.2)
5 (3.7)
7.5 (5.8)
10 (7.5)
15 (11)
20 (15)
25 (18)
30 (22)
40 (29)
50 (37)
60 (44)
75 (55)
100 (74)
125 (93)
150 (111)
N = Non Regen
R = Regen
1
005
Third Position
Rating
R
Fourth Position
Type
OPTIONS
Fifth Position
B 460V AC
003
005
007
010
015
020
025
030
040
050
060
075
100
125
150
200
250
300
400
500
600
3 (2.2)
5 (3.7)
7.5 (5.6)
10 (7.5)
15 (11)
20 (15)
25 (18)
30 (22)
40 (29)
50 (37)
60 (44)
75 (55)
100 (74)
125 (93)
150 (111)
200. (149)
250 (186)
300 (224)
400 (298)
500 (373)
600 (448)
DS
MB
L10
L11
DB
FS2
FS3
PE
AC
HAB
HAP
HA1
HA2
1203GD1
1203GD2
1203GK1
1203GK2
1203GK5
NOTE: Refer to page
14 for additional option
information.
U
380/415V AC
ADC
7
29
55
110
265
380/415
2.4 (1.8)/2.8 (2.1)
12 (9)13.8 (10.3)
24 (17.9)/27.6 (20.8)
48 (35.8)/55.2 (41.2)
120 (89.5)/138 (102.9)
1 Regen (R) required for reversing applications
Catalog Numbering
Convention