* DEFAULTS may be adjusted per installation as required.
651 20 ACCEL TIME
652 10 DECEL TIME
659 400 KI VELOCITY LOOP
660 150 KP VELOCITY LOOP
661 65535 KF VELOCITY LOOP
663 150 FORWARD BRIDGE CURRENT
LIMIT
664 150 REVERSE BRIDGE CURRENT LIMIT
713 0 PROCESS TRIM FILTER
714 0 INTEGRAL PRELOAD
715 0 KI INTEGRAL GAIN
716 4096 KP PROPORTIONAL GAIN
717 -165 PROCESS TRIM LOW LIMIT
718 165 PROCESS TRIM HIGH LIMIT
719 -1 P/I REGULATOR OUTPUT GAIN
720 150 OVERLOAD PENDING LEVEL
721 0 PROCESS TRIM LOW SUM
722 1750 PROCESS TRIM HIGH SUM
724 75 ABSOLUTE OVERSPEED
725 10 EXTERNAL OVERTEMP DELAY
726 10 SCR OVERTEMP DELAY
727 2 STALL DELAY
728 1 AC LINE TOLERANCE DELAY
730 1 FIELD FAILURE DELAY
731 15 TACH LOSS CEMF
732 0.5 TACH LOSS VELOCITY
733 1 ARM BRIDGE TYPE
734 155 K DISCONTINOUS
735 1659 KP ARMATURE LOOP
736 136 KI ARMATURE LOOP
737 16384 KP FIELD LOOP
738 512 KI FIELD LOOP
* 739 12350 K ARM VOLTS
* 740 7200 K AC VOLTS
Table 2: Parameter List, Factory (Initial) Settings (Continued)