Owner manual

Chapter 4
Hardware Description
125 – 300 HP, 230VAC
250 – 600 HP, 460VAC
4-4
Surge Suppression – Surge Suppressor 1 MOV (Fig. 4.2) protects the
armature power bridge from high voltage line spikes and line surges.
SCR Packaging – In 346 – 980A bridges (125 – 600HP) SCRs are
packaged as individual hockey-puck type SCRs. Two SCRs connected in
antiparallel in one of six legs of the bridge is referred to as an SCR cell.
There are 6 SCR cells per bridge for armature regenerative construction.
The non-regenerative version has 6 SCRs only. There are no reversing
SCRs (1R through 6R).
SCR Cell Snubbers – Each SCR cell is protected from rapid rate of
voltage change (dv/dt) using a resistor and capacitor network (referred to
as a Cell Snubber) connected in parallel with the SCR cell.
Figure 4.3
Armature Regenerative Bridge Components (Output)
AB0444A