Instruction Manual
6–6 Start-Up
Program Input Mode
Cycle Input Power
4. It is important that the Input Mode selected be programmed into the drive.
Since the controlinputs areprogrammable, incorrectoperation can occur ifan
improper mode is selected. The factory default mode (”Status”) disables all
inputs except Stop and Enable. Verify your control scheme against the infor-
mation providedin Chapter3 or4 andprogram the [Input Mode]parameteras
follows:
A. Fromthe Status Display, presstheEnterkey (oranykey).“Choose Mode”
will be displayed.
B. Press the Increment (or Decrement) key until “Program” is displayed. If
Program is not available, programming is password protected. Refer to
Chapter 5 for Password mode information.
C. Press Enter.
D. Press the Increment key until “Setup” is displayed.
E. Press Enter.
F. Press SELect. The first character of line 2 will now flash.
G. PresstheIncrementorDecrementkeysuntilthedesiredmodeisdisplayed,
then press Enter.
In addition to the mode, Inputs 3-8 can also be programmed (if defaults
are not desired). See Chapter 7 for parameter information. Use the steps
above as a guide if input programming is desired.
H. Press the ESCape key (3 times) to return to the Status Display.
I. Removepowertothedrive.WhentheHIMDisplayisnolongerilluminated,
reapply power.
Important: Display must go blank for input mode programming changes
to take effect.
Choose Mode
EEProm
Choose Mode
Program
Metering
Setup
Input Mode
Status
Input Mode
3 Wire
Stopped
+0.00 Hz
Advanced Start-Up Procedure
Press these keys . . . while following these steps . . . The HIM Display will show . . .
or
or