Instruction Manual

756 Programming
Motor
Control
This group of parameters defines basic motor control.
[Control Select]
Selectsthemotorcontrolmethodforthedrive.Thedefault
setting provides full stator flux control that is suitable for
most applications.
Additional selections are offered to optimally tune
performance:
Two volts/Hertz modesare available; oneusing simple
voltage boost and one for complete configurability.
Thesemayberequiredforspecialmotorsorunmatched
multi-motor installations.
TheEconomizemodeoffersalltheadvantagesofstator
flux control plus the added feature of an “auto-econo-
mizer.” If a motor remains lightly loaded, the drive will
reduce output voltage (and therefore output kW) in or-
dertoreduce theenergy(operating)costs ofthelightly
loadedmotor.This canresultin upto 20%kW savings.
Parameter Number 9
Parameter Type Read and Write
Factory Default “Sens Vector”
Units Display Drive
“Economize” 0 Stator Flux control with Economize
“Sens Vector” 1 Stator Flux control
“Fixed Boost” 2 V/Hzw/programmedaccel/runboost
“Full Custom” 3 V/Hz with full configuration
[Flux Amps Ref]
Used in “Economize” & “Sens Vector” modes - Sets the
valueofamps requiredto maintainfull motorflux.If setto
zero, the drive willuse an internal value basedon [Motor
NPAmps]anddrivekW(HP).RefertoChapter6forsetup
information.
Parameter Number 192
Parameter Type Read and Write
Display Units / Drive Units 0.1 Amp / 4096 = Drive Rated Amps
Factory Default 0.0 Amps
Minimum Value 0.0 Amps
Maximum Value 75.0% of Drive VT Rated Amps
Voltage
0
0
Frequency
Run Boost
Start Boost
B
A
Base Voltage
Base Frequency
Voltage
0
0
Frequency
Motor Rated Maximum
Start Boost
Break Voltage
Break Frequency
Maximum
Base Voltage
Base Frequency
Maximum Voltage
Maximum Frequency
Motor Rated
Run Boost
Full Custom
Fixed
Default
Voltage
0
0
Frequency
Factory Default
Motor Rated
and
Maximum
Motor Rated
and
Maximum
Base/Maximum Voltage
Base/Maximum Frequency