This group of parameters contains binary information to display which group of adapters
are issuing control commands.
Each Owner Parameter contains a bit for each adapter.
Thedrivewillset anadapter’s bitto“1” whenthat adapter
is issuing a logic command and to “Zero” when no
command is being issued.
A Status description (bit ENUM) is displayed on line 1
(except Series A HIMs below version 3.0).
[Stop Owner]
This parameter displays which adapters are presently
issuing a valid stop command.
Parameter Number 102
Parameter Type Read Only
Units Display Drive
“0” 0 Stop Input Not Present
“1” 1 Stop Input Present
[Direction Owner]
This parameter displays which adapter currently has
exclusive control of direction changes.
If [Freq Select 1] or [Freq Select 2] is set to “Analog In 0”
andanAnalog OptionBoardwith bipolarinput (LA6,LA7)
isinstalled, thatinput (designated“Analog In0”) willhave
exclusive ownership ofdirection. Bit7 of[Direction Mask]
mustnotbesetto“0”andnootherdevicecanhaveclaimed
ownership of direction (i.e. TB5 - Run Reverse). If either
condition is true, a fault will be issued.
Parameter Number 103
Parameter Type Read Only
Units Display Drive
“0” 0 Non-Owner
“1” 1 Current Owner
[Start Owner]
This parameter displays which adapters are presently
issuing a valid start command.
Parameter Number 104
Parameter Type Read Only
Units Display Drive
“0” 0 Start Input Not Present
“1” 1 Start Input Present
[Jog Owner]
This parameter displays which adapters are presently
issuing a valid jog command.
Parameter Number 105
Parameter Type Read Only
Units Display Drive
“0” 0 Jog Input Not Present
“1” 1 Jog Input Present
[Reference Owner]
This parameter displays which adapter currently has the
exclusive control of the selection of the command
frequency source.
Parameter Number 106
Parameter Type Read Only
Units Display Drive
“0” 0 Non-Owner
“1” 1 Current Owner
[Accel Owner]
This parameter displays which adapter has exclusive
control of selecting [Accel Time 1] or [Accel Time 2].
Parameter Number 107
Parameter Type Read Only
Units Display Drive
“0” 0 Non-Owner
“1” 1 Current Owner
TB4-TB6
Adapter 1
Adapter 2
Adapter 3
Adapter 4
Adapter 5
Adapter 6
Not Used
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Owners Display