Instruction Manual
7–44 Programming
Masks
[Alarm Mask 1]
Stand-Alone Version Only
Controls which alarm conditions will
activate the alarm contact (refer to
Chapter3-TB3-TB4)andset thealarm
bit (bit 6) in [Drive Status 1].
A Status description (bit ENUM) is
displayed on line 1 (except Series A
HIMs below version 3.0).
Parameter Number 206
Parameter Type Read and Write
[Alarm Mask 2]
Stand-Alone Version Only
Controls which alarm conditions will
activate the alarm contact (refer to
Chapter3-TB3-TB4)andset thealarm
bit (bit 6) in [Drive Status 1].
Setting thebit to “1”allows thealarm to
occur. Setting the bit to “0” causes the
drive to ignore that alarm.
A Status description (bit ENUM) is
displayed on line 1 (except Series A
HIMs below version 3.0).
Parameter Number 271
Parameter Type Read and Write
Bus Charging
Regenerating Current Limit
Regenerating Voltage Limit
Line Loss In Progress
Motor StalledGround Warning
Bit 15 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Mtr Overload
Sync Loss
Bit 14
Hardware Current Limit
Motoring Current Limit
Motor OL Trip
Auto Reset
Phase Loss
Heatsink Temp
Auxiliary Input
4-20 mA Loss
Motor Therm
Bit 15 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0Bit 14
Unused
Encoder Loss
Load Loss
Enc Cnt Max
Enc Cnt Set
Voltage Check