Terminal Block TB2 and TB3 - Terminal block TB2 is located at the bottom of the Main Control Board.
Control and Signal Wiring TB2 is an eighteen position terminal block with markings of 1 to 18.
Terminal block TB3 is a twelve position terminal block located on optional
interface boards L1, L2 or L3 directly above terminal block TB2. If either
L1, L2 or L3 is present, refer to Appendix A — Logic Interface Options
for wiring details.
TB2
GND
GND
M1
+DC
–DC
M3
M2
L1
L2
L3
HAZARDOUS VOLTAGE ON
CAPACITORS WHEN NEON
LIGHT IS ON. REMOVE POWER
AND WAIT 60 SEC. BEFORE
SERVICING.
CAUTION
BULLETIN 1336VT ADJUSTABLE FREQUENCY AC DRIVE
1
2
4
3
5
6
7
8
9
10
11
12
13
14
15
16
17
18
CAUTION
HAZARDOUS VOLTAGE ON CAPACITORS
WHEN NEON LIGHT IS ON. REMOVE POWER
AND WAIT 60 SECONDS BEFORE SERVICING.
ATTENTION
TENSION DANGEREUSE AU NIVEAU DES
CONDENSATEURS QUAND LES NEONS SONT
ALLUMES. COUPER LE COURANT ET
ATTENDRE 60 SECONDES AVANT DE
COMMENCER L'ENTRETIEN.
VORSICHT
AN DEN KONDENSATOREN BESTEHT
HOCHSPANNUNGSGEFAHR, WENN DS NEON-
LICHT AUFLECUDHTET. STROM UNTER-
BRECHEN UND 60 SEK. WARTEN BEVOR
SERVICEARBEITEN DURCHGEFÜHRT WERDEN.
ATTENZIONE
TENSIONE PERICOLOSA SUI CONDENSATORI
QUANDO LA LUCE AL NEON È ACCESA.
TOGLIERE L'ALIMENTAZIONE ED ASPETTARE 60
SECONDI PRIMA DI PRESTARE MANUTENZIONE.
¿¬|– [¥
†[Ÿ Ÿº |]º] ¬Ÿ[ ¿|] Ÿº][, <|>/º ¥‡º
~|[º ¥‡º Ÿº][ <|>/º ¿Ÿº¿|]
|]º] ¬Ÿ[ ¿|] Ÿº][, <|>/º ¥‡º<|>/º ¥‡º
¬Ÿ[ ¿|]
PRECAUCION
AVOLTAJE PERLIGROSO EN LS CAPACITORES
CUANDO LA LUZ DE NEON ESTÉ ENCENDIO.
CORTE LA ENERGIA Y ESPERE 60 DEGUNDOS
ANTES DE DAR SERVICIO.
Freq
P
R
Enter
P
R
Start
Jog
Stop
C1
C2
➀
➁
SW1
J9 –– Pins 7 and 8
Pins 9 and 10
J8 –– Pins 11 and 12
Spare Jumper
Location
Bus Charge
Neon Indicator