Manual

Logic Interface Options
Appendix A
A-15
5.6k 5.6k 5.6k 5.6k 5.6k 5.6k 5.6k 5.6k 5.6k 5.6k 5.6k 5.6k 5.6k 5.6k 5.6k5.6k5.6k 5.6k
19 20 21 22 23 24 25 26 27 28 29 30
I
K9K8K7K6K5K4K3
K2K1
Aux EnableStart Stop Jog Rev SW2 Speed
Select
User 115V AC Supply
EARTH
GROUND
3-Wire Control
2-Wire Control TB3
TB3
19 20 21 22 23 24 25 26 27 28 29 30
User 115V AC Supply
Start/Stop
Contact
INTERFACE
COMMON
SW1
EARTH
GROUND
1336MODL3 115V AC
Logic Interface Board (cont.)
Maximum Recommended
Signal Wire Group Wire Size Torque
Terminal 19, Interface Common Start 3 14 AWG 7 In-Lbs
Terminal 20, Interface Common Stop 3 14 AWG 7 In-Lbs
Terminals 21, 25, 29 Interface Common 3 14 AWG 7 In-Lbs
Terminal 22, Interface Common Jog 3 14 AWG 7 In-Lbs
Terminal 23, Interface Common Reverse 3 14 AWG 7 In-Lbs
Terminal 24, Interface Common SW1 3 14 AWG 7 In-Lbs
Terminal 26, Interface Common SW2 3 14 AWG 7 In-Lbs
Terminal 27, Interface Common Speed Select 3 14 AWG 7 In-Lbs
Terminal 28, Interface Common Auxiliary 3 14 AWG 7 In-Lbs
Terminal 30, Interface Common Enable 3 14 AWG 7 In-Lbs
W
ire group number chart, page 6-3.
2.5mm
2
.
.79N-m.
This signal must be present to permit the drive to operate from any control source.