45
1336 FORCE Frame D to PowerFlex 700S Frame 5 Dimensions
)
Drive Frame
Dimensions
(1)
mm (in.)
(1)
Refer to drive User Manuals for location and size of motor lead knockouts.
Weight
(3)
kg (lbs.)
(3)
PowerFlex 700S weights include HIM, DriveLogix controller with ControlNet daughtercard, Hi-Resolution Encoder Option, and 20-COMM-C ControlNet adapter.
A (700S Slim) AA (700S Expanded) BC (Max.) D E Drive Drive & Packaging
1336T D 381.5 (15.02) na 1240.0 (48.82) 270.8 (10.66) 325.9 (12.83) 1216.2 (47.88) na 108.9 (240)
700S 5
308.0 (12.16) 339.9 (13.38)
644.5 (25.37)
(2)
(2)
When using the supplied junction box (Frame 5, 100 HP PowerFlex 700S drives only), add an additional 45.1 mm (1.78 in.) to this dimension.
275.4 (10.84) 225.0 (8.86) 625.0 (24.61) 37.19 (82.0) 42.18 (93.0)
D
A
E
B
Mounting Holes (4)
C Max.
HOT surfaces can cause severe burns
CAUTION
E
12.5
(0.49)
6.5 (0.26)
B
D
A
259.1 (10.20)
37.6
(1.48)
C
Lifting Holes - 4 Places
12.7 (0.50) Dia.
312
(12.28)
S
AA