Frame to AC Drive Rating Cross Reference
400V AC Input (using 700S kW ratings values)
480V AC Input (using 700S HP ratings values)
ND kW HD kW
ND Cont.
Output Amps 1336 Frame PF 700S Frame
0.75 0.55 2.1 B 1
1.5 1.1 3.5 B 1
2.2 1.5 5.0 B 1
4.0 3.0 8.7 B 1
5.5 4.0 11.5 B 1
7.5 5.5 15.4 B 1
11 7.5 22 B 1
15 11 30 B 2
18.5 15 37 B 2
22 18.5 43 B 3
30 22 56 B, C 3
37 30 72 C 3
45 37 85 C 4
55 45 105 C, D 5
55 45 125 D 5
75 55 140 D 6
90 75 170 D, E 6
110 90 205 E 6
132 110 260 E 6
132 110 261 E 9
160 132 300 E 9
200 160 385 E 10
250 200 460 E, F, G 10
250 250 500 F, G 10
315 250 590 F, G 11
355 315 650 F, G 11
400 355 730 G 11
ND HP HD HP
ND Cont.
Output Amps 1336 Frame PF 700S Frame
10.75 2.1 B 1
21.5 3.4 B 1
32 5.0 B 1
53 8.0 B 1
7.5 5 11 B 1
10 7.5 14 B 1
15 10 22 B 1
20 15 27 B 2
25 20 34 B 2
30 25 40 B, C 3
40 30 52 B, C 3
50 40 65 C 3
60 50 77 C 4
75 60 96 C, D 5
100 75 125 D 5
125 100 156 D 6
150 125 180 D, E 6
200 150 248 E 6
200 150 261 E 9
250 200 300 E 9
300 250 385 E 10
350 300 460 E, F, G 10
450 350 500 F, G 10
500 450 590 F, G 11
500 500 650 G 11
600 500 730 G 11
700 600 820 H 12
800 700 920 H 12