Chapter 5
Programming Parameters
5–62
Vqe Maximum (Constant HP)
[Vqe Max]
Parameter Number 244
Parameter Type Sink
Display Units x.x volts
Drive Units 16 = 1 volt (L–N)
Factory Default 367.0 volts
Minimum Value 0.0 volts
Maximum Value 468.8 volts
Vde Minimum (Constant HP)
[Vde Min]
Parameter Number 245
Parameter Type Sink
Display Units x.x Volts
Drive Units 16 = 1 volt line to neutral peak
Factory Default 3.0 volts
Minimum Value 0.0 volts
Maximum Value 50.0 volts
Kslip (Base Slip Frequency)
[Base Slip Freq]
Parameter Number 246
Parameter Type Sink
Display Units x.xx Hz
Drive Units 256 = 1Hz/unit torque
Factory Default 0.832 Hz
Minimum Value 0.000 Hz
Maximum Value 10.000 Hz
Q axis voltage at which the motor enters
field weakening. Parameter calculated by
autocommissioning routine and MUST
NOT BE CHANGED. Data represented as
x.x volts
D axis voltage below which the adaption to
motor changes in the torque control is dis-
abled. Parameter calculated by autocom-
missioning routine and MUST NOT BE
CHANGED. Data represented as x.x volts
Base slip frequency of the motor.
Parameter calculated by autocommission-
ing routine. Data represented as x.x Hz.
Kslip Maximum
[Base Slip Fr Max]
Parameter Number 247
Parameter Type Sink
Display Units x.xx Hz
Drive Units 256 = 1Hz/unit torque
Factory Default 2.00 Hz
Minimum Value 0.00 Hz
Maximum Value 30.00 Hz
Maximum slip frequency allowed on the
motor. Parameter calculated by autocom-
missioning routine and MUST NOT BE
CHANGED. Data represented as x.x Hz.
Kslip Minimum
[Base Slip Fr Min]
Parameter Number 248
Parameter Type Sink
Display Units x.xx Hz
Drive Units 256 = 1Hz / unit torque
Factory Default 0.50 Hz
Minimum Value 0.00 Hz
Maximum Value 10.00 Hz
Minimum slip frequency allowed on the
motor. Calculated by autocommissioning
routine and MUST NOT BE CHANGED.
Data represented as x.x Hz.
Ki – Slip Regulator
[Ki Slip]
Kp – Flux Regulator
[Kp Flux]
Kp – Slip Regulator
[Kp Slip]
Parameter Number 251
Parameter Type Sink
Display Units x
Drive Units None
Factory Default 300
Minimum Value 0
Maximum Value 32767
Parameter Number 250
Parameter Type Sink
Display Units x
Drive Units None
Factory Default 306
Minimum Value 0
Maximum Value 32767
Parameter Number 249
Parameter Type Sink
Display Units x
Drive Units None
Factory Default 153
Minimum Value 0
Maximum Value 32767
Proportional Gain of the slip regulator.
This parameter MUST NOT BE
CHANGED.
Data represented as x.
Integral Gain of the slip regulator. This
parameter MUST NOT BE CHANGED.
Data represented as x.
Proportional Gain of the Flux regulator.
This parameter MUST NOT BE
CHANGED.
Data represented as x.