Owner's manual

227Installation/Wiring
Example 2
Input Mode 7 Application is to follow a local HIM unless a preset
speed is selected. The drive is programmed as follows:
[Freq Select 1] = Adapter 1
[Freq Select 2] = Preset Freq 1
[Preset Freq 1] = 10 Hz.
[Preset Freq 2] = 20 Hz.
[Preset Freq 3] = 30 Hz.
Contact operation for the speed select switch is described in the table
below. Since Input Mode 7 does not offer a Speed Select 3 input,
[Preset Freq 4-7] are not available.
26
Speed Select 2
Speed Select 1
Local
See Table
1
2
3
27
28
Switch
Speed Select Input
Parameter Used
Programmed
Switch
Position
1 (#28)
2 (#27)
Parameter
Used
for S
p
eed Ref.
Programmed
Settin
g
Local Open Open [Freq Select 1] Adapter 1
1 Closed Open [Freq Select 2] Preset Freq 1
2 Open Closed [Preset Freq 2] 20 Hz.
3 Closed Closed [Preset Freq 3] 30 Hz.