Owner's manual
Appendix A
Specifications and
Supplemental Information
Appendix A provides specifications and supplemental information
including a parameter cross reference and derate information.
Protection
200-240V Drive 380-480V Drive 500-600V Drive
AC Input Overvoltage Trip: 285V AC 570V AC 690V AC
AC Input Undervoltage Trip: 138V AC 280V AC 343V AC
Bus Overvoltage Trip: 405V DC 810V DC 975V DC
Bus Undervoltage Trip: 200V DC 400V DC 498V DC
Nominal Bus Voltage: 324V DC 648V DC 810V DC
Heat Sink Thermistor: Monitored by microprocessor overtemp trip.
Drive Overcurrent Trip
Software Current Limit: 20 to 160% of VT rated current.
Hardware Current Limit: 180 to 250% of VT rated current (dependent on drive rating).
Instantaneous Current Limit: 220 to 300% of VT rated current (dependent on drive rating).
Line transients: up to 6000 volts peak per IEEE C62.41-1991.
Control Logic Noise Immunity: Showering arc transients up to 1500 volts peak
2
.
Power Ride-Thru: 15 milliseconds at full load.
Logic Control Ride-Thru: 0.5 seconds minimum, 2 seconds typical.
Ground Fault Trip: Phase-to-ground on drive output.
Short Circuit Trip: Phase-to-phase on drive output.
Environment
Altitude: 1000 m (3300 ft) max. without derating.
Ambient Operating Temperature
IP00, Open: 0 to 50 degrees C (32 to 122 degrees F).
IP20, NEMA Type 1 Enclosed: 0 to 40 degrees C (32 to 104 degrees F).
IP54, NEMA Type 12 Enclosed: 0 to 40 degrees C (32 to 104 degrees F).
IP65, NEMA Type 4 Enclosed: 0 to 40 degrees C (32 to 104 degrees F).
Storage Temperature (all constructions): –40 to 70 degrees C (–40 to 158 degrees F).
Relative Humidity: 5 to 95% non-condensing.
Shock: 15G peak for 11ms duration (±1.0ms).
Vibration: 0.006 inches (0.152 mm) displacement, 1G peak.
Agency Certification:
U.L. Listed
CSA Certified
Q
E
T
N
O
C
D
N
I
6
L
6
5
D
E
T
S
I
L
Q
E
T
N
O
C
D
N
I
6
L
6
5
D
E
T
S
I
L
Marked for all applicable directives
1
Emissions EN 50081-1
EN 50081-2
EN 55011 Class A
EN 55011 Class B
Immunity EN 50082-1
EN 50082-2
IEC 801-1, 2, 3, 4, 6, 8 per EN 50082-1, 2
Low Voltage EN 60204-1
PREN 50178
1
Note: Installation guidelines called out in Appendix C must be adhered to.
2
Excludes Pulse Train Input.
Specifications