Owner's manual

550 Programming
[PI Preload] Firmware 4.01 & later
Sets the value used to preload the PI intergrator
when Set Output or Preload Int bits equal 1 in
[PI Config].
Parameter Number 225
Parameter Type Read/Write
Display Units / Drive Units 0.01 Hertz / ±32767 = Maximum Freq
Factory Default 0.00 Hz
Minimum Value 8.33% of [Maximum Freq]
Maximum Value + 8.33% of [Maximum Freq]
PI Reference
PI Reference
Select
pi reference
PI Config.sqrt_fdbk
PI Config.inv_error
PI Config.reset_int
PI Feedback
Freq Command
PI Error
Master Frequency Reference
Process KI
s
Process KP
Integral Term = 0
PI + Clamp
PI Clamp
PI Output
Speed
Adder
Output Frequency
Speed
Command
Speed
Ramp
pi feedback
PI Feedback
Select
Compute
Speed
Accel
Control
+
1
+
+
PI Config.zero_clamp
speed ramp>0
+
+
PI Output
+32767
Parameter 65
32767
32767
+32767
0
0
Process PI