User Manual - Firmware 1.xxx-6.xxx Instruction Manual

A–14 Specifications and Supplemental Information
Encoder Interface Wiring Option L4/L4E & L7E Wiring
Option L4/L4E - Contact Closure Interface Board Requirements
Contacts must be capable of operating at 10 mA current levels
without signal degradation. Reed type input devices are recom-
mended.
The L4/L4E option is compatible with the following Allen-Bradley
PLC
modules:
1771-OYL
1771-OZL
Option L7E - Contact Closure Interface Board Requirements
Circuits used with Option L7E must be capable of operating with
low = true logic. In the low state, external circuits must be capable of
a sinking current of approximately 10 mA to pull the terminal voltage
low to 3.0V DC or less. In the high state, external circuits must let the
terminal voltage rise to a voltage of 4.0-5.0V DC. Reed type input
devices are recommended.
The L7E option is compatible with the following Allen-Bradley
PLC
modules:
1771-OYL
1771-OZL
L4/L4E
L7E
19 20 21 22 23 24 25 26 27 28 29 30 31 32
AA
ENC
RET
ENC
12V
33 34 35 36
Typical
Typical
Isolated
+5V
Isolated
Ground
0.1
µ
f 0.1
µ
f
0.1
µ
f
10.7k
470 470
12V
681
100
90.9
5V
JP4
IGND
10.7k
TB3
19 20 21 22 23 24 25 26 27 28 29 30 31 32
AA
ENC
RET
ENC
12V
33 34 35 36
Typical
Typical
Isolated
+5V
Isolated
Ground
0.1
µ
f0.1
µ
f
0.1
µ
f
10.7k
470 470
12V
681
173
576
5V
J1/J2
IGND
10.7k
TB3
Current
Limit
Feedback
0.5A
0.001
B
B
2200pf
255