User Manual - Firmware 1.xxx-6.xxx Instruction Manual

Programming 6–47
Owners
[Decel Owner]
This parameter displays which adapter has exclusive con-
trol of selecting [Decel Time 1] or [Decel Time 2].
Parameter Number 108
Parameter Type Read Only
Units
Display Drive
“0” 0 Non-Owner
“1” 1 Current Owner
[Fault Owner]
This parameter displays which adapter is presently reset-
ting a fault.
Parameter Number 109
Parameter Type Read Only
Units
Display Drive
“0” 0 Non-Owner
“1” 1 Current Owner
[MOP Owner]
This parameter displays which adapters are currently is-
suing increases or decreases in MOP Command
Frequency.
Parameter Number 110
Parameter Type Read Only
Units
Display Drive
“0” 0 Non-Owner
“1” 1 Current Owner
[Traverse Owner]
Displays which SCANport adapter is presently enabling
the traverse function.
Parameter Number 306
Parameter Type Read Only
Units
Display Drive
“0” 0 Non-Owner
“1” 1 Current Owner
[Sync Owner]
Displays which SCANport adapter is presently enabling
the sync function.
Parameter Number 309
Parameter Type Read Only
Units
Display Drive
“0” 0 Non-Owner
“1” 1 Current Owner
[Local Owner]
This parameter displays which adapter has requested ex-
clusive control of all drive logic functions. If an adapter is
in local lockout, all other functions (except stop) on all other
adapters are locked out and non-functional. Local control
can only be obtained when the drive is not running.
Parameter Number 179
Parameter Type Read Only
Units
Display Drive
“0” 0 Non-Owner
“1” 1 Current Owner