User Manual - Firmware 1.xxx-6.xxx Instruction Manual
Programming 6–41
Ratings
This group contains a number of “Read Only” parameters that display drive operating char-
acteristics.
[Rated Volts]
This parameter displays the rated input voltage of the drive.
Parameter Number 147
Parameter Type Read Only
Display Units / Drive Units 1 Volt / Volts
Display Drive Rated Input Voltage
[Rated Amps]
This parameter displays the rated output current of the
drive based on the CT/VT selection.
Parameter Number 170
Parameter Type Read Only
Display Units / Drive Units 0.1 Amp / Amps x 10
Display Drive Rated Output Amps
[Rated kW]
This parameter displays the rated kW of the drive based
on the CT/VT selection.
Parameter Number 171
Parameter Type Read Only
Display Units / Drive Units kW / kW x 100
Display Drive Rated Output kW
[Firmware Ver.]
This parameter displays the version number of the drive
firmware.
Parameter Number 71
Parameter Type Read Only
Display Units / Drive Units None / Version x 100
Display 0.00
[Cntrl Board Rev]
This parameter displays the revision number of the drive
Main Control Board.
Parameter Number 251
Parameter Type Read Only
Display Units / Drive Units None / Version x 100
Display 0.00
[Rated CT Amps]
This parameter displays the rated output current of the
drive.
Parameter Number 148
Parameter Type Read Only
Display Units / Drive Units 0.1 Amp / Amps x 10
Display Drive Rated Output Amps
[Rated CT kW]
This parameter displays the rated CT kW of the drive.
Parameter Number 149
Parameter Type Read Only
Display Units / Drive Units kW / kW x 100
Display Drive Rated Output kW
[Rated VT Amps]
This parameter displays the rated output current of the
drive.
Parameter Number 198
Parameter Type Read Only
Display Units / Drive Units 0.1 Amp / Amps x 10
Display Drive Rated Amps
[Rated VT kW]
This parameter displays the rated VT kW of the drive.
Parameter Number 199
Parameter Type Read Only
Display Units / Drive Units kW / kW x 100
Display Drive Rated kW