This workbook is Publication # 1336F-IN007A-EN-P January 2002 Last Reveision 1/21/02 These records can be printed to provide a written record of parameter changes made to a 1336 PLUS 2 drive. Some manpulation of the spreadsheets may be necessary based on you selection of a printer.
Par # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 Parameter Name Output Voltage % Output Curr % Output Power Last Fault Freq Select 1 Freq Select 2 Accel Time 1 Decel Time 1 Control Select Stop Select 1 Bus Limit En DC Hold Time DC Hold Level Run On Power Up Reset/Run Time Minimum Freq Base Frequency Base Voltage Maximum Freq Maximum Voltage Spare MOP Increment Output Power Jog Frequency
Par # 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 Parameter Name Anlg Out 0 Abs Anlg Out 0 Lo Anlg Out 0 Hi Drive Status 2 Anlg In 0 Lo Anlg In 0 Hi Anlg In 1 Lo Anlg In 1 Hi Input Mode TB3 Term 22 Sel TB3 Term 23 Sel TB3 Term 24 Sel TB3 Term 26 Sel TB3 Term 27 Sel TB3 Term 28 Sel Anlg In 2 Lo Anlg In 2 Hi Anlg Signal
Par # 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 Parameter Name Data In D1 Data In D2 Data Out A1 Data Out A2 Data Out B1 Data Out B2 Data Out C1 Data Out C2 Data Out D1 Data Out D2 Process 1 Par Process 1 Scale Process 1 Txt 1 Process 1 Txt 2 Process 1 Txt 3 Process 1 Txt 4 Process 1 Txt 5 Process 1 Txt 6 Process 1 Txt
1336 PLUS II Parameter Record Customer Name ____________________ Plant Machine # ____________________ ____________________ Process Number ____________________ Other Data ____________________ Date Programmed ___________________ SW Version ____________________ Drive Cat # ____________________ Drive Ser # ____________________
1336 PLUSII Parameter Record Machine # Date programmed Drive Serial # Par # 1 2 3 4 5 Parameter Name Minimum Value Maximum Value Output Voltage % Output Curr % Output Power Last Fault Freq Select 1 0 0% 200% Drive Rated Output Power None 200% Rated Drive Output Voltage 200% Rated Drive Output Current +200% Drive Rated Output Power None Use Last Analog In 0 Analog In 1 Analog In 2 Pulse Ref MOP Adapter 1 Adapter 2 Adapter 3 Adapter 4 Adapter 5 Adapter 6 Preset 1 Preset 2 Preset 3 Preset 4 Preset 5 Pres
1336 PLUSII Parameter Record Machine # Date programmed Drive Serial # Par # Parameter Name 38 Overload Amps 39 Flt Clear Mode Minimum Value Maximum Value 20% of Drive Rated Amps 115% of Drive Rated Amps Disabled Enabled Disabled Enabled Induction Sync Reluc Sync PM 10.0 Hz 7.0 Hz 10 Sec A & B Frame Drives = 8 kHz C Frame Drives & Up = 6 kHz 4096 English FRANCAIS ESPANOL Italiano Deutsch Japanese Portuguese Nederlands 9.
1336 PLUSII Parameter Record Machine # Date programmed Drive Serial # Par # Parameter Name Minimum Value Maximum Value 63 Encoder Freq 64 Set Defaults -400.00 Hz 65 66 67 68 69 Freq Command Output Freq Output Pulses Serial Password Drive Direction -400.00 Hz -400.00 Hz 0 Auto Tune Rel +400.00 Hz Ready Store to EE Rcll frm EE Default Init +400.00 Hz +400.00 Hz 65535 70 71 72 73 74 75 76 77 Heatsink Temp Firmware Ver.
1336 PLUSII Parameter Record Machine # Date programmed Drive Serial # Par # 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 Parameter Name Data In D1 Data In D2 Data Out A1 Data Out A2 Data Out B1 Data Out B2 Data Out C1 Data Out C2 Data Out D1 Data Out D2 Process 1 Par Process 1 Scale Process 1 Txt 1 Process 1 Txt 2 Process 1 Txt 3 Process 1 Txt 4 Process 1 Txt 5 Process 1 Txt 6 Process 1 Txt 7 Process 1 Txt 8 MOP Freq Anlg In 0 Freq Anlg In 1 Freq Anlg
1336 PLUSII Parameter Record Machine # Date programmed Drive Serial # Par # Parameter Name Minimum Value Maximum Value 149 Rated CT kW Factory Default Read Only Page 5 of 13 Programmed Value
1336 PLUSII Parameter Record Machine # Date programmed Drive Serial # Par # Parameter Name Minimum Value 150 4-20mA Loss Sel 151 Maximum Speed 152 Encoder Type 0 Hz 153 Motor Poles 154 Anlg Out 0 Offst 155 Flying Start En 156 FStart Forward 157 FStart Reverse 158 CR1 Out Select 0 Hz 0 Hz 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 0.00 Hz 0% 0.0 Amps -200% Drive Rating -200% Drive Rating 0 0 -8.33% of [Base Frequency] -8.33% of [Base Frequency] -8.33% of [Base Frequency] 1.
1336 PLUSII Parameter Record Machine # Date programmed Drive Serial # Par # Parameter Name Minimum Value 175 CR3 Out Select 176 CR4 Out Select 177 Motor NP RPM 178 Motor NP Hertz 179 Local Owner 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 Process 2 Par Process 2 Scale Process 2 Txt 1 Process 2 Txt 2 Process 2 Txt 3 Process 2 Txt 4 Process 2 Txt 5 Process 2 Txt 6 Process 2 Txt 7 Process 2 Txt 8 Motor NP Volts Motor NP Amps Flux Amps Ref KP Amps IR Drop Volts
36 PLUSII Parameter Record Machine # Date programmed Drive Serial # Par # Parameter Name Minimum Value Maximum Value 1 Bus Charging Hardware Current Limit Motoring Current Limit Regenerating Current Limit Regenerating Voltage Limit Line Loss In Progress Mtr Overload Motor Stalled Ground Warning Auxilliary Input Heatsink Temp Sync Loss Phase Loss 4-20 mA Loss Motor OL Trip Auto Reset 255 206 Alarm Mask 1 207 208 209 210 211 212 213 Fault Data Time Data 1 Time Data 3 Time Data 5 Time Data 7 DC Bus M
1336 PLUSII Parameter Record Machine # Date programmed Drive Serial # Par # Parameter Name Minimum Value 231 Hold Level Sel 232 Current Lmt Sel 233 Anlg Out 0 Abs 234 Anlg Out 0 Lo 235 Anlg Out 0 Hi 236 Drive Status 2 -300.0% -300.0% 237 238 239 240 241 -300.0% -300.0% -300.0% -300.0% Anlg In 0 Lo Anlg In 0 Hi Anlg In 1 Lo Anlg In 1 Hi Input Mode 242 TB3 Term 22 Sel 243 TB3 Term 23 Sel Maximum Value DC Hold Lvl Analog In 0 Analog In 1 Current Lmt Analog In 0 Analog In 1 Disabled Enabled +300.
1336 PLUSII Parameter Record Machine # Date programmed Drive Serial # Par # Parameter Name 244 TB3 Term 24 Sel 245 TB3 Term 26 Sel 246 TB3 Term 27 Sel Minimum Value Maximum Value Unused Jog Speed Sel 1 Speed Sel 2 Speed Sel 3 1st Accel 2nd Accel 2 Acc/1 Acc 1st Decel 2nd Decel 2 Dec/1 Dec Clear Fault Aux Fault Local Ctrl Traverse Sync PI Enable PI Reset Dig Pot Up Dig Pot Dn Stop Type Forward Reverse Rev/For Run Reverse CB Precharge Unused Jog Speed Sel 1 Speed Sel 2 Speed Sel 3 1st Accel 2nd Accel 2
1336 PLUSII Parameter Record Machine # Date programmed Drive Serial # Par # Parameter Name Minimum Value 247 TB3 Term 28 Sel 248 Anlg In 2 Lo 249 Anlg In 2 Hi 250 Anlg Signal Loss -300.0% -300.
1336 PLUSII Parameter Record Machine # Date programmed Drive Serial # Minimum Value Maximum Value 272 Meas. Volts 273 Meas.
1336 PLUSII Parameter Record Machine # Date programmed Drive Serial # Par # 291 292 293 294 295 296 297 298 299 300 301 302 303 Parameter Name Minimum Value Maximum Value Load Loss Level Load Loss Time PI Max Error DSP Comm Errors Max PWM Depth Tuned Flux Amps Tuned IR Drop Run Time Lower Run Time Upper Spare DSP Code Rev Main Boot Rev Current Lmt En 20% 0 Sec -400.00 Hz 100% 30 Sec 400.00 Hz 304 Traverse Dec 305 Traverse Mask 0.00 Sec 306 Traverse Owner 307 Sync Time 308 Sync Mask 0.