User Manual
Operation and Programming
Chapter 5
5-44
Bias and Gain Settings
➊ 100% of Output Frequency
100% of Input Frequency Signal
0%
Parameter 53 = 0%
Acceleration
When Bias Frequency
is Less Than Gain
a Directly Proportional
Input Frequency Signal
is Produced
Bias Frequency Less Than Gain
Parameter 54
➊ 100% of Output Frequency = 50 Hz if Parameter 3 = 50
60 Hz if Parameter 3 = 60
Paramer 15 if Parameter 3 = FF
➊ 100% of Output Frequency
100% of Input Frequency Signal
Bias Frequency Greater Than Gain
0%
0%
Parameter 53
noitareleceD
When Bias Frequency
is Greater Than Gain
an Inversely Proportional
Input Frequency Signal
is Produced
Parameter 54
Parameter 53 -- Bias Frequency
Units = Hertz
Range = 00.00/400.0
Factory
Setting
= 00.00
From 00.50-400.0 Hz, Parameter 53 sets the Bias Frequency in .01 Hz
increments.
From 100.0-400.0 Hz, Parameter 53 sets the Bias Frequency in 0.1 Hz
increments.
Parameter 54 -- Gain Frequency
Units = Hertz
Range = 00.50/400.0
Factory
Setting
= 60.00
From 00.50-400.0 Hz, Parameter 54 sets the Gain Frequency in .01 Hz
increments.
From 100.0-400.0 Hz, Parameter 54 sets the Gain Frequency in 0.1 Hz
increments.