User Manual

Operation and Programming
Chapter 5
5-20
Max Speed Settings Important: The maximum allowable drive output frequency will be
determined by the lowest programmed value of any of the following
parameters:
Parameter 3 Frequency Range
Parameter 15 Maximum Frequency
Parameter 51 Upper Frequency Clamp
Parameter 53 Bias Frequency –– If Parameter 53 is Higher Than
Parameter 54
Parameter 54 Gain Frequency –– If Parameter 54 is Higher Than
Parameter 53
Max Speed Settings
100% of Output Frequency
0%
0%
Parameter 16
100% of Output Voltage
noitareleccA
Parameter 15
0%
0%
100% of Output Frequency
Parameter 15 = Parameter 16
100% of Output Voltage
noitareleccA