User Manual
Installation and Wiring
Chapter 4
4-13
If You Use
FAA or GAA Units
Lugs are required to terminate wires for FAA or GAA units at the Power Terminal Block.
Power Recommended
Rating Wire Wire
Code Group ❶ Size ❷
FAA 2
6 A
WG (16.0mm
2
)
GAA 2
3 A
WG (30.0mm
2
)
❶
Wire group number chart, page 46.
❸
UL Listed crimp connectors are required and must be installed using the proper crimping tool.
Crimp connectors must be sized to the wire size chosed.
When using crimp connectors on terminal studs that are not isolated from each other
,
a minimum spacing of 0.4 Inches (10.16mm) is required.
(Power T
erminal Block Cover)
CAUTION
:
230/208VA.C.
Input Voltage Only
Use 75 Degree C ❷ AWG Copper Wire
Use U.L. Listed Crimp Connectors ❸
Select
from the following drive input fuses.
Drive Rating F
AA Fuse Size 100AFuse T
ype 600V Class K5 UL Listed or Equivalent
Drive Rating GAA
Fuse Size 125AFuse T
ype 600V Class K5 UL Listed or Equivalent