User Manual
Preventive Maintenance and
Troubleshooting Common Drive Problems
Appendix B
B-6
Auxiliary Interlock
DC Bus Neon Light
Drive Nameplate
Control and Signal Wiring Terminal Block
Power Terminal Block
Lock Switch
Figure B1 -- 3/45HP (.554kW)
1333 parts, switches and terminal blocks shown in Figures B-1 and B-2 are
referenced throughout the remainder of this chapter.
1. The motor will not run --
AU
is displayed.
Are Terms 16 and 17 at the Control and Signal Wiring Terminal Block
jumpered? Is an auxiliary interlock installed between T
erms 16 and 17?
Remove the cause of the interlock fault or jumper terminals 16 and 17 if an
auxiliary interlock is not required.
No
Yes
Contact your nearest AB representative for application assistance.