User Manual User Manual
AC Induction Motors 11
Epic Connector or Plain Cable Connections
Motor Application Data Maximum Safe Speed
The speeds given in Table B are the maximum mechanically safe
operating speeds for frames with standard construction. These speeds
must not be exceeded under any condition. Motor control must hold
the maximum speed under any load condition including no-load
within the maximum safe speed. Drive systems whose design
characteristics inherently prevent the AC motor from exceeding the
motor maximum safe operating speed must prevent the motor from
exceeding the maximum safe speed if a single component failure
should occur.
Table B
Maximum Safe Speed
With special construction maximum safe speed may differ from the
above values. In all cases, the maximum safe speed is indicated on the
motor nameplate.
Important: Normal operating speeds must be limited to those listed in
order to meet nameplate rating and assure validity of
warranty.
Pin Signal Color Pin Signal Color
1 Common Black 6 5-15V Red
2 B Green 7 B (NOT) Yellow
3 A Blue 8 A (NOT) Gray
4 Z Violet 9 Z (NOT) Orange
5 No Connection – 10 Shield Braid
!
ATTENTION: The machinery builder and/or user are
responsible for assuring that all drive train mechanisms, the
driven machine, and process material are capable of safe
operation at the maximum speed at which the machine will
operate. Failure to observe these precautions could result in
personal injury.
Frame Diameter Maximum Safe Speed
L180 7200 RPM
L210 5000 RPM
L250 5000 RPM
L280 5000 RPM
L320 4000 RPM
L360 3750 RPM
L400 3750 RPM
L440 2700 RPM