Owner's manual

1329I-5.5 Integrated Drive/Motor — January, 2000
Series B Summary of Changes
Additional Start Mode Selection Feature
Local operator units can now be controlled from either the operator controls or the
terminal block.
Terminal Block Stop Input
The terminal block stop input and local operator stop key are now active for all start
mode selections.
Zero Speed Operation
The minimum speed has been reduced from 90 RPM (3 Hz) to zero.
Storage Temperature Range Extended
The storage temperature rating has been extended from 70°C to 85°C.
CE Mark
The unit now conforms to the EMC and LVD directives for CE. An optional line
filter is required.
CE Line Filter Option
Single and three phase line filters are now available. This option can be mounted
internally or is packaged for external mounting.
DeviceNet Communication Option
A DeviceNet communication option is now available, which is installed inside the
unit. Refer to the
Bulletin 1329I DeviceNet Option User Manual
for more
information.
Drive Parameters Added
The unit now has drive display parameters and drive program parameters. These
parameters can be viewed or changed through a DeviceNet connection. Refer to the
Bulletin 1329I DeviceNet Option User Manual
for more information.
Series B Application/Installation Considerations
Keep the following in mind if you are replacing a Bulletin 1329I Series A with a Series
B unit.
Minimum Speed
The minimum speed has been reduced from 90 RPM (3 Hz) to 0 RPM (0 Hz).
Terminal Block Stop Input
Terminal block stop input must be present for local operator control units.