User Manual

A-2
Technical Specifications
1329I-5.0 Integrated Drive/Motor — January, 1999
Maximum continuous output current:
Maximum output current:
Important:
Maximum current ratings above are for the CT rating. When VT is
selected, the maximum output current will be limited to 110%.
Output frequency:
3 to 120 Hz
Carrier frequency:
•8 kHz
Input Voltage Unit HP
Output Current
(Motor Rated Amps)
460 VAC 1 HP 1.7 A
460 VAC 2 HP 3.2A
460 VAC 3 HP 4.5 A
460 VAC 5 HP 6.9 A
230 VAC 1 HP 3.4 A
230 VAC 2 HP 6.4 A
230 VAC, 1-phase 1 HP 3.4 A
230 VAC, 1-phase 2 HP 6.4 A
115 VAC 1 HP 6.8 A
Input Voltage Unit HP
Maximum Output Current
(150% Rated Amps)
460 VAC 1 HP 2.55 A
460 VAC 2 HP 4.8 A
460 VAC 3 HP 6.75 A
460 VAC 5 HP 10.35 A
230 VAC 1 HP 5.1 A
230 VAC 2 HP 9.6 A
230 VAC, 1-phase 1 HP 5.1 A
230 VAC, 1-phase 2 HP 9.6 A
115 VAC 1 HP 10.2 A