User Manual
Programming
5-44
Diagnostics Group (continued)
[
Drive Alarm
]
Parameter # 60
[Drive
Alarm]
Parameter Type Read Only
This parameter displays which alarm condition is present
This
parameter
displays
which
alarm
condition
is
present
when bit 6 of [Drive Status] is high (set to 1)
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
“Soft Cur Lim”
“Line Loss”
“4-20mA Loss
“Bus Changing”
N/A
“Hard Cur Lim”
“Bus Overvolt”
Hard Current Limit
Software Currnt Limit
Bus Overvoltage
Line Loss
4-20mA Loss
Bus Changing
Not Used
N/A Not Used
[
In
p
ut Status
]
Parameter # 55
[Input
Status]
Parameter Type Read Only
This parameter displays the open (0) and closed (1) status
This
parameter
displays
the
open
(0)
and
closed
(1)
status
of inputs at TB2. Refer to Figure 2.7 through Figure 2.10
for description of terminal connections.
Bit 7 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
“Start TB2-6”
“Stop TB2-8”
“Rev TB2-13”
“Jog TB2-14”
“SW1 TB2-16”
“SW2 TB2-17”
“SW3 TB2-18”
N/A
Bit 6
TB2–6 Start/Run Forward
TB2–8 Stop
TB2–13 Reverse/Run Reverse
TB2–14 JOG
TB2–16 SW1
TB2–17 SW2
TB2–18 SW3
Not Used