Chapter 5 –Programming
5-23
Advanced Set Up Group (cont.)
[DC
Hold
Le
v
el
]
Parameter # 13 Factory Default 0 Volts
[DC
Hold
Le
v
el
]
Parameter Type Read & Write Minimum 0 Volts
This parameter value sets the DC voltage applied to the
motor during braking when the [Stop Select] is set to
either ‘‘DC Brake” or ‘‘Ramp”. IMPORTANT: When setting
this parameter, begin at a low voltage and continue
increasing until sufficient holding torque is achieved and
the drive output current rating is not exceeded.
Units 1 Volt Maximum 25% of Max. Drive Rated Volts
[D
B
Ena
b
le
]
Parameter # 11 Factory Default ‘‘Disabled”
[D
B
Ena
b
le
]
Parameter Type Read & Write
This parameter enables the use of external dynamic brake
res
i
s
t
ers
by
d
i
s
abling th
e
int
er
nal
r
am
p
re
g
u
lation.
IMPO TA T:rsver/
Units None
Settings
‘‘Enabled”
Permits dynamic brake operation
res
i
s
t
ers
by
d
i
s
abling th
e
int
er
nal
r
am
p
re
g
u
lation.
IMPORTANT: Dynamic braking is not available for 1/2
through 1HP (0.37 to 0.75 kW) units rated 230 Volt.
‘‘Disabled”
Permits Ramp Regulation
[
Mo
t
or
Type
]
Parameter # 41 Factory Default ‘‘Induc/Reluc”
[
Mo
t
or
Type
]
Parameter Type Read & Write
This parameter should be set to match the type of motor
conn
e
ct
ed
to th
e
dr
i
ve
.
Units None Settings ‘‘Induc/Reluc”
Requires No Additional Setting for use with
induction/reluctance rated motors
conn
e
ct
ed
to th
e
dr
i
ve
.
‘‘Sync PM”
Requires [Stop Select] to be set to a selection other
than ‘‘DC Brake” when used with Synchronous
Permanent Magnet Motors