High Level System With Summing Configuration.
10. On the input denormalization setup CD track prompt, select track two of the 3Sixty.3 setup disk.
11. The Normalize Source Unit Response graph is now displayed (empty). The color code for each output channel initialized in step #4 is displayed to the
right of the graph. Select the “Auto Normalize” button to flatten the response of each output channel. This may take up to 5 min, The output for each channel
will now be displayed in the frequency response graph. The input to the 3Sixty.3 can also be displayed in the frequency response graph by selecting “Input
Channels” from the Plot tab in the upper right hand corner.
12. The device setup is now complete, reduce your system setup and the EQ can now be adjusted.
NOTE The outputs of the 3Sixty.3 are about to be un-muted internally, reduce your volume level
to ensure the speakers are not damaged.
High Level Sample System