User Guide Instruction Manual
Robustel GoRugged R3000 User Guide
RT_UG_R3000_v.2.0.0 17.01.2014 51 / 131
Confidential
Transparent Over Rlink
Modbus Over Rlink
RS485 @ Serial
Item
Description
Default
Baud-rate
115200
Data bit
8
Parity
None
Stop bit
1
Protocol
Transparent: Router will transmit the serial data transparently without any
protocols.
Modbus: Router will transmit the serial data with Modbus protocol.
Transparent
Mode @Transparent
Select
TCP Client
Local Port
@Transparent
Enter the Local port for TCP or UDP.
0
Multiple Server
@Transparent
and port, and enable or disable
port.
Note: This section will not be displayed if you select “TCP server” in “Mode”.
Null
Enable Protocol
@Transparent
Tick to enable protocol advanced setting.
Disable
Local IP @
Transparent
This item will show up When you enable any VPN tunnel of R3000, it means
serial data can be matched to this local IP address and be transmitted or
received via VPN tunnel.
0