Unit installation
  Ed. 05/2009 
User, Installation and Service Manual for F1 Gas Unit Heaters 
6 
TECHNICAL CHARACTERISTICS 
MODEL  UNIT F1 21 F1 31  F1 41  F1 51  F1 61  F1 81 
Appliance Category    II
2H3+ 
Appliance type    C
13
 - C
33 
- B
23 - 
C
63 
- C
53 
Nominal heat input (5)  kW 23,08 30,77 37,15 48,35 61,32 77,14 
  BTU 78804 105046 126841 165072 209357 263369 
Nominal heat output  kW  21  28  33,8  44  55,8  70,2 
 BTU 71698 95597 115407 150224 190520 239668
Efficiency (5)  % 91 91 91 91 91 91 
Nominal air flow (1)  m
3
/h 2000 2700 3400 4200 5200 7800 
Temperature rate  K  31,1  30,7  29,5  31  31,8  26,7 
Gas Consumption (2) Natural Gas  m
3
/h 2,43 3,25 3,93 5,11 6,49 8,16 
 LPG G30 
 LPG G31 
kg/h 
kg/h 
1,80 
1,78 
2,42 
2,38 
2,93 
2,87 
3,81 
3,74 
4,84 
4,75 
6,09 
5,97 
Inlet gas pressure   Natural Gas 
  LPG. G30 
  LPG G31 
mbar 
20 
30 
37 
Diameter gas inlet  "  3/4F 
Pipe Diameter    air  mm  80 
 flue mm  80 
Voltage    230V - 50Hz 
Wattage W 260 400 450 640 900 
Operating temperature  °C  0° +35°
(4)
Fuse A 6,3 
Throw 
(residual air speed >1m/s) 
(3) 
m 14 16 20 22 25 29 
Noise level 6 m distance 
    in free field 
dB(A)
41 
43 
44 
46 
47 
49 
    in tipycal installation  dB(A) 53  55  56  57  60  63 
Weight kg 55 59 68 80 90 108 
Table 1 
1  At 20°C - 1013mbar 
2  At 15°C - 1013mbar 
3  THROWS FOR GUIDANCE ONLY. THROW DEPENDS ON HEIGHT OF THE BUILDING, MOUNTING HEIGHT OF THE HEATER, ROOM TEMPERATURE AND LOUVRE 
SETTING. 
4  WARNING: THE ROOM OPERATIONAL TEMPERATURE IS BETWEEN 0° AND +35°C ;THE APPLIANCE’S COMPONENTS OPERATIONAL TEMPERATURE IS BETWEEN 
0° AND +60°C 
5  DATA REFERED TO THE LOW HEAT VALUE (9,45 kWh/m
3
 - 15°C 1013 mbar) 
WITH THE AIM OF CONTINUOUSLY IMPROVING THE QUALITY OF ITS PRODUCTS, THE 
MANUFACTURER RESERVES THE RIGHT TO VARY ABOVE INFORMATION WITHOUT ANY PRIOR 
NOTICE. 