Instructions
6969
www.cel-robox.com
5.0 AutoMaker Soware
• Retract Length (mm)
This value specifies the distance the filament is ‘pulled back’ (retracted) at the
end of an extrusion path. This is used to release pressure before the needle
valve begins to close.
• Retract/Unretract Speed (mm/s)
This value specifies the speed that the filament is ‘pulled back’ (retracted) at
the end of an extrusion path and also pushed back in (unretracted) at the
start of the next.
• Help Text
This box displays a brief explanation of the setting which is highlighted
(changes on mouseover).