Data Sheet

2/22/2018 ROBOTIS e-Manual
http://emanual.robotis.com/docs/en/dxl/x/xm430-w210/ 8/34
Address
Size
(Byte)
Data Name Description Access
Initial
Value
636 1
Indirect Data
31
Indirect Data 31 RW 0
659 1
Indirect Data
54
Indirect Data 54 RW 0
660 1
Indirect Data
55
Indirect Data 55 RW 0
661 1
Indirect Data
56
Indirect Data 56 RW 0
Caution Protocol 1.0 does not support addresses greater than 256.
Therefore, Indirect Address 29 ~ 56 and Indirect Data 29 ~ 56 can
only be accessed with Protocol 2.0.
2. 4. Control Table Description
Caution Data in the EEPROM Area can only be written when the
value of Torque Enable(64) is cleared to ‘0’.
2. 4. 1. Model Number(0)
This address stores model number of the DYNAMIXEL.
2. 4. 2. Firmware Version(6)
This address stores firmware version of the DYNAMIXEL.
2. 4. 3. ID(7)
The ID is a unique value in the network to identify each
DYNAMIXEL with an Instruction Packet. 0~252 (0xFC) values
can be used as an ID, and 254(0xFE) is occupied as a
broadcast ID. The Broadcast ID(254, 0xFE) can send an
Instruction Packet to all connected DYNAMIXELs
simultaneously.
Note Please avoid using an identical ID for multiple
DYNAMIXELs. You may face communication failure or may not be
able to detect Dynamixels with an identical ID.
2. 4. 4. Baud Rate(8)
Baud Rate determines serial communication speed between a
controller and DYNAMIXELs.
Value Baud Rate Margin of Error
XM430-W210
Back to Top ▲