- ROBOTIS Dynamixel RX-28 User's Manual
DYNAMIXEL 
RX-28 
  The returned Status Packet is as the following 
  Status Packet : 0XFF 0XFF 0X00 0X02 0X00 0XFD 
   ID LENGTH ERROR CHECKSUM 
Note the ID of this Dynamixel actuator is now changed to 1 after the RESET instruction. 
4-6. SYNC WRITE 
Function
  Used for controlling many Dynamixel actuators at the same time. The communication 
time decreases by the Synch Write instruction since many instructions can be 
transmitted by a single instruction. However, you can use this instruction only when the 
lengths and addresses of the control table to be written to are the same. Also, the 
broadcasting ID needs to be used for transmitting. 
ID 
0XFE 
Length 
(L + 1) * N + 4 (L: Data length for each Dynamixel actuator, N: The number of Dynamixel 
actuators) 
Instruction  0X83 
Parameter1
  Starting address of the location where the data is to be written 
Parameter2  The length of the data to be written (L) 
Parameter3  The ID of the 1st Dynamixel actuator 
Parameter4  The 1st data for the 1st Dynamixel actuator 
Parameter5  The 2nd data for the 1st Dynamixel actuator 
Data for the 1st Dynamixel actuator 
… 
Parameter L+3  The Lth data for the 1st Dynamixel actuator 
Parameter L+4 
The ID of the 2nd Dynamixel actuator 
Parameter L+5 The 1st data for the 2nd Dynamixel actuator 
Data for the 2nd Dynamixel actuator
Parameter L+6   
The 2nd data for the 2nd Dynamixel actuator 
… 
Parameter 2L+4 The Lth data for the 2nd Dynamixel actuator 
…. 
Example 5  Setting the following positions and velocities for 4 Dynamixel actuators
  Dynamixel actuator with an ID of 0: to position 0X010 with a speed of 0X150 
Dynamixel actuator with an ID of 1: to position 0X220 with a speed of 0X360 
23