Example 3  To obtain the status packet of a Dynamixel with ID=1 
  Instruction Packet : 0XFF 0XFF 0X01 0X02 0X01 0XFB` 
     ID LENGTH INSTRUCTION CHECKSUM 
  The returned Status Packet is as follow; 
  Status Packet : 0XFF 0XFF 0X01 0X02 0X00 0XFC 
     ID LENGTH ERROR CHECKSUM 
4-5. RESET 
Function  Restore the condition of the Control Table of the Dynamixel back to the Factory 
Default values. 
Length  0X02 
Instruction  0X06 
Parameter  NONE 
Example 4  Reset Dynamixe with ID=0 
  Instruction Packet : 0XFF 0XFF 0X00 0X02 0X06 0XF7` 
  ID LENGTH INSTRUCTION CHECKSUM 
  The returned Status Packet is as follows;   
  Status Packet : 0XFF 0XFF 0X00 0X02 0X00 0XFD 
ID LENGTH ERROR CHECKSUM 
  Please note that after a RESET instruction, the ID of the Dynamixel is changed 
to 1. 