Owner manual

21
English Translation by: Tribotix Pty Ltd 
www.tribotix.com 
DYNAMIXEL 
DX-116 
Function  REG_WRITE  instruction  is  similar  to  the  WRITE_DATA  instruction,  but  the 
execution timing is different. When the Instruction Packet is received the values 
are  saved  into  the  Buffer  and  the  Write  instruction  is  under  a  standby  status. 
The Registered Instruction register (Address 0x2C) is set to 1. After an Action 
Instruction Packet is received the registered Write instruction is executed.   
Length  N+3 (The number of Write Data bytes is N) 
Instruction  0X04 
Parameter1  Start Address for Write Data 
Parameter2  1
st
 Data to Write 
Parameter3  2
nd
 Data to Write 
Parameter N+1  N
th
 Data to Write 
ACTION 
Function  Execute the WRITE instruction written by REG_WRITE   
Length  0X02 
Instruction  0X05 
Parameter  NONE 
  The ACTION instruction is useful when multiple Dynamixels needs  to  move 
simultaneously.  When  controlling  multiple  units,  slight  time  delays  occur 
between the  1
st
 unit  to receive  an  instruction and  the last  one. The Dynamixel 
approach fixes this problem through the use of the ACTION instruction. 
Broadcasting  When sending ACTION instructions to move more than two Dynamixel units, the 
Broadcast ID (0XFE) should be utilised. 
4-4. PING 
Function  Used to request a specific Dynamixel status packet or to check the existence of 
a Dynamixel with a particular ID 
Length  0X02 
Instruction  0X01 
Parameter  NONE 