Owner manual

19
English Translation by: Tribotix Pty Ltd 
www.tribotix.com 
DYNAMIXEL 
DX-116 
4. Instruction Set and Examples 
  The following Instructions are available. 
4-1. WRITE_DATA 
Function  Write data into the control table of the Dynamixel   
Length  N+3 (Writing Data is N) 
Instruction  0X03 
Parameter1  Start Address of the Area to write Data 
Parameter2  1st Data to write 
Parameter3  2
nd
 Data to write 
Parameter N+1  N
th
 Data to write 
Example 1  Set ID of connected Dynamixel as 1 
  Write 1 into the Address 3 of the Control Table. The ID is transmitted  using 
Ins truction 
Name
Function Value
Number of 
Parameter
PING
No action. Used to obtain a Dynamixel 
Status Packet.
0x01 0
READ_DATA Read the values in the Control Table.  0x02 2
WRITE_DATA Write the values to the Control Table.  0x03 2 ~
REG_WRITE
Similar to WRITE_DATA, but stay in 
standby mode until the write upon the 
action instruction. 
0x04 2 ~
ACTION Start the action registered by REG_WRITE 0x05 2
RESET
Change the values of the Dynamixel in the 
control table back to the Factory Default 
Values. 
0x06 0