Owner manual

13
English Translation by: Tribotix Pty Ltd 
www.tribotix.com 
DYNAMIXEL 
DX-116 
Control Table  The Control Table consists of data for conditions and movement of the 
Dynamixel.  By  writing  the  values  in  the  control  table,  you  can  move  the 
Dynamixel and detect the condition of the Dynamixel. 
RAM and EEPROM  The data values for the RAM Area will be set to the default initial  values  on 
power  on.  The  data  values  for  the  EEPROM  Area  are  non-volatile  and  will  be 
available next power on. 
Initial Value  The Initial Value column of the control table shows the Factory  Default Values 
for the case of EEPROM Area Data. For the RAM Area Data, the initial  value 
column gives the power on data values.   
  Please  note  the  following  meanings  for  data  assigned  to  each  address  in  the 
control table. 
Address 0x00,0x01  Model Number
.    In the case of the DX-116, the value is 0X0074(116). 
Address 0x02  Firmware Version
.   
Address 0x03  ID
. Unique ID number to identify the Dynamixel. Different ID’s are required to 
be assigned to “linked” Dynamixels.   
Address 0x04  Baud Rate
.    Determines the Communication Speed. The Calculation method is:- 
  Speed(BPS)    = 2000000/(Address4+1) 
Note  A maximum Baud Rate error of 3% is within the UART communication tolerance. 
Address 0x05  Return Delay Time
. The  time taken  after sending  the Instruction  Packet, to 
Data Value as per Major Baud Rate
Address4
BPS Set Target BPS Error
1 1000000.0 1000000.0 0.000%
3 500000.0 500000.0 0.000%
4 400000.0 400000.0 0.000%
7 250000.0 250000.0 0.000%
9 200000.0 200000.0 0.000%
16 117647.1 115200.0 - 2.124%
34 57142.9 57600.0 0.794%
103 19230.8 19200.0 - 0.160%
207 9615.4 9600.0 - 0.160%