Request is:
34 AB 00 00 00 0D 02 10 03 E8 00 03 06 09 00 00 00 FF FF
where
BITS DESCRIPTION
34AB Unique transaction identifier (chosen randomly)
0000 Protocol Identifier (Modbus)
000D Length
02 SlaveID
10 Function Code 16 (Preset Multiple Registers)
03E8 Address of the first register
0003 Number of registers to write to
06 Number of data bytes to follow (3 registers x 2
bytes/register = 6 bytes)
0900 Value written to register 0x03E9 (ACTION REQUEST =
0x09 and GRIPPER OPTIONS = 0x00): rACT = 1 for
, "Activate Gripper" rMOD=0 for "Go to Basic Mode"
, rGTO = 1 for "Go to Requested Position"
0000 Value written to register 0x03EA (GRIPPER OPTIONS
2 = 0x00 and POSITION REQUEST = 0x00): rPR =
0/255 for full opening of the Gripper (partial
opening would also be possible)
FFFF Value written to register 0x03EB (SPEED = 0xFF and
FORCE = 0xFF): full speed and full force
Response is:
34 AB 00 00 00 06 02 10 03 E8 00 03