Data Sheet
XDC2xxx Motor Controller Datasheet 7
Enabling Analog Commands
Enabling Analog Commands
For safety reasons, the Analog command mode is disabled by default. To enable the Analog mode, use the PC
utility and set Analog in Command Priority 2 or 3 (leave Serial as priority 1). Note that by default the additional
securities are enabled and will prevent the motor from starting unless the potentiometer is centered, or if the
voltage is below 0.25V or above 4.75V. The drawing shows suggested assignment of Pot 1 to ANA5 and Pot 2 to
ANA4. Use the PC utility to enable and assign analog inputs.
CAN Bus Operation
The controller can interface to a standard CAN Bus network, using 4 possible protocols: Standard CANOpen, and
two simplified proprietary schemes (MiniCAN, RawCAN and RoboCAN). Please refer to the User Manual for
details.
USB communication
Use USB only for configuration, monitoring and troubleshooting. USB is not a reliable communication method
when used in a electrically noisy environments and communication will not always recover after it is lost without
unplugging and replugging the connector, or restarting the controller. Always prefer RS232 communication when
interfacing to a computer.
Status LED Flashing Patterns
After the controller is powered on, the Power LED will turn on, indicating that the controller is On. The Status LED
will be flashing at a 2 seconds interval. The flashing pattern provides operating or exception status information.
6 CANL CAN Low
14 5VOut
7 CANH CAN High
15 ANA6 DIN6 Unused
8 RC2 ANA2 DIN2 RCRadio2
Note 1: Analog command is disabled in factory default configuration.
TABLE 5.
Connector Pin Power Dout Com RC Ana Dinput Default Config
RS232/USB Mode
Idle - Waiting for Command
RC Pulse Mode
Analog Mode
FIGURE 7. Normal Operation Flashing Patterns