Datasheet
16 SBLM23xx Motor Controller Datasheet Version 1.2 July 25, 2020
TABLE 10.
Parameter Measure Point Min Typ Max Units
Fast fuse to install(3)(4) SBLM23xx 20 2 x 20 Amps
SBLM23xxS 2 x 20 Amps
Overload protection - Check Note 5
Note 1: Thermal protection will protect the controller power
Note 2: Max allowed power out starts lowering at minimum of range, down to 0 at max of range
Note 3: There are two power terminals. Fuse should be installed in both of them for safety.
Note 4: In dual channel controller, for operating only one channel install 20A fuse and for operating both channels 2 x 20A fuse
should be installed. Power source must be capable to blow the fuse instantly in case of short circuit
Note 5: Current limiting mechanism available through firmware. External overload motor protection can be used if required
(provided by user)
STO Specifications
TABLE 11.
Parameter Measure Point Min Typ Max Units
STO Input High Level Ground to STO input pin 6 30 Volts
STO Input Low Level Ground to STO input pin 0 1 Volts
STO Response Time Input to output change 5 msec
STO Operating temperature – 20 55 ºC
STO Storage temperature – 20 70 ºC
Humidity 5 95 %
IP degree IP30
Operating Altitude 2000 m
Cable Length 2 m
EMC Immunity According to IEC 61800-3 and IEC 61800-5-2 Annex E
CE Declaration Available at www.roboteq.com
Mechanical Specifications
TABLE 12.
Parameter Measure Point Min Typ Max Units
Weight Board 215 (0.47) g (lbs)
Power Connectors Wiring Terminals 12 22 AWG