Advanced Digital Motor Controller User Manual 265
Command Arguments Description
ECHOF OffOn Enable/Disable Serial Echo
EE Address Data Store User Data in Flash
MDAL Option Modbus Data Alignment
MNOD ID Modbus Node ID
RS485 Enable Enable RS485
RSBR BitRate Set RS232 bit rate
RWD Timeout Serial Data Watchdog
SCRO Port Select Print output port for scripting
SKCTR Channel Center Spektrum Center
SKDB Channel Deadband Spektrum Deadband
SKLIN Channel Linearity Spektrum Linearity
SKMAX Channel Max Spektrum Max
SKMIN Channel Min Spektrum Min
SKUSE Channel Port Assign Spektrum port to
motor command
STO Enable Safe Torque Off
TELS String Telemetry string
ACS - Analog Center Safety
HexCode: 0B
Description:
This parameter enables the analog safety that requires that the input be at zero
or centered before it can be considered as good. This safety is useful when oper-
ating with a joystick and requires that the joystick be centered at power up before mo-
tors can be made to run. On mutli-channel controllers, this configuration acts on all analog
command inputs, meaning that all joysticks must be centered before any one becomes
active.
Syntax Serial: ^ACS nn
~ACS
Syntax Scripting: setconfig(_ACS, nn)
Number of Arguments: 1
Argument 1: Enable
Type: Unsigned 8-bit
Min: 0 Max: 1
Default: 1
Where:
nn =
0: Safety disabled
1: Safety enabled