Datasheet
16 SBL23xx Motor Controller Datasheet Version 1.0 November 4, 2020
Scripting
TABLE 11.
Parameter Measure Point Min Typ Max Units
Scripting Flash Memory Internal 32000 Bytes
Max Basic Language programs Internal 1000 3000 Lines
Integer Variables Internal 4096 Words (1)
Boolean Variables Internal 8192 Symbols
Execution Speed Internal 50000 100000 Lines/s
Note 1: 32-bit words
Thermal Specifications
TABLE 12.
Parameter Measure Point Min Typ Max Units
Case Temperature Case – 40 85 (1) ºC
Thermal Protection range Case 80 90 (2) ºC
Power Dissipation Case 10 Watts
Thermal resistance Power MOSFETs to plate 0.6 ºC/W
Humidity Case 95 %
Ambient temperature Ambient 55 ºC
Pollution Degree - PD 2
Fast fuse to install(3)(4) SBL2360 20 2 x 20 Amps
SBL2360S 2 x 20 Amps
SBL2396 13 2 x 13 Amps
SBL2396S 2 x 13 Amps
Overload protection - Check Note 5
Note 1: Thermal protection will protect the controller power
Note 2: Max allowed power out starts lowering at minimum of range, down to 0 at max of range
Note 3: There are two power terminal inputs. Fuse should be installed in both of them for safety.
Note 4: In dual channel controller, for operating only one channel install 20A fuse and for operating both channels 2 x 20A fuse
should be installed. Power source must be capable to blow the fuse instantly in case of short circuit
Note 5: Current limiting mechanism available through firmware. External overload motor protection can be used if required
(provided by user)