Datasheet
Electrical Specifications
SBL23xx Motor Controller Datasheet 13
Power Stage Electrical Specifications (at 25ºC ambient)
TABLE 6.
Parameter Measure point Model Min Typ Max Units
Input Continuous current Power source current All 40 Amps
Output Voltage Ground to U, V, W wires All 0 (1) 60 (2) Volts
Power Control Voltage Ground to Power Control wire All 0 (1) 65 Volts
Minimum Operating Voltage VBat or Pwr Ctrl wires All 10 (3) Volts
Over Voltage protection range Ground to VMot All 5 60 (4) 63 Volts
Under Voltage protection range Ground to VMot All 0 5 (4) 63 Volts
Idle Current Consumption VMot or Pwr Ctrl wires All 50 100 (5) 150 mA
ON Resistance (Excluding wire
resistance)
VMot to U, V or W. Ground to
U, V or W
SBL23xx 3.3 mOhm
SBL23xxS 1.65 mOhm
Max Current for 30s Motor current SBL23xx 30 Amps
SBL23xxS 60 Amps
Continuous Max Current per
channel
Motor current SBL23xx 20 (6) Amps
SBL23xxS 40 (6) Amps
Current Limit range Motor current SBL23xx 10 30 30 Amps
SBL23xxS 20 60 60 Amps
Stall Detection Amps range Motor current SBL23xx 10 30 (7) 30 Amps
SBL23xxS 20 60 (7) 60 Amps
Stall Detection timeout range Motor current All 1 500 (8) 65000 msec
Short Circuit Detection
threshold (9)
Between Motor wires or
Between Motor wires and
ground or Between Motor
wires and Vmot
SBL23xx 85 (10) Amps
SBL23xxS 190 (10) Amps
Motor Acceleration/
Deceleration range
Motor Output All 100 500 (11) 65000 msec
Power cable thickness Power input and output All 12 AWG
Note 1: Negative voltage will cause a large surge current. Protection fuse needed if battery polarity inversion is possible
Note 2: Can be even higher because of regeneration voltage. Never inject a DC voltage from a battery or other fixed source
Note 3: Minimum voltage must be present on VBat or Power Control wire
Note 4: Factory default value. Adjustable in 0.1V increments
Note 5: Current consumption is lower when higher voltage is applied to the controller’s VBat or PwrCtrl wires
Note 6: Estimate. Limited by case temperature. Current may be higher with better cooling
Note 7: Factory default value. Adjustable in 0.1A increments
Note 8: Factory default value. Time in ms that Stall current must be exceeded for detection
Note 9: Controller will stop until zero command given in case of short circuit detection
Note 10: Approximate value
Note 11: Factory default value. Time in ms for power to go from 0 to 100%