12 SBL23xx Motor Controller Datasheet Version 1.0 November 4, 2020
FIGURE 12. STO input levels effects on controller output
The STO function is compliant to:
IEC 61800-5-2:2007, SIL 3
IEC 61508:2010, SIL 3
IEC 62061:2005, SIL 3
ISO 13849-1:2015, Category 3 Performance Level e
Important Warning
Activating STO does lead to no more torque generation on the motor. The motor will not be actively
stopped but run out. In case of a multiple fault in the power stage a rotation might occur.
Electrical Specifications
Absolute Maximum Values
The values in the table below should never be exceeded, permanent damage to the controller may result.
TABLE 5.
Parameter Measure point Min Typ Max Units
Battery Leads Voltage Ground to VBat 60 (2) Volts
Reverse Voltage on Battery Leads Ground to VBat – 1 Volts
Power Control Voltage Ground to Pwr Control wire 60 (2) Volts
Motor Leads Voltage Ground to U, V, W wires 60 (2) Volts
Digital Output Voltage Ground to Output pins 30 Volts
Analog and Digital Inputs Voltage Ground to any signal pin on 15-pin & Hall
inputs
30 Volts
RS232 I/O pins Voltage External voltage applied to Rx pin 30 (3) Volts
Case Temperature Case – 40 85 ºC
Humidity Case 100 (4) %
Note 1: Only PELV/SELV voltages shall be used
Note 2: Can be even higher because of regeneration voltage. Never inject a DC voltage from a battery or other fixed source
Note 3: No voltage must be applied on Tx pin
Note 4: Non condensing