Data Sheet

7 SBL23xx Motor Controller Datasheet Version 1.2 March 27, 2018
Hall Sensor vs Motor Output sequencing
TABLE 1.
Pin Number 1 2 3 4 5 6
Signal 5V Hall C Hall B Hall A Ground
Hall Sensor vs Motor Output sequencing
The controller requires the Hall sensors inside the motor to be 120 degrees apart. The
controller’s 3-phase bridge will activate each of the motor winding according to the se-
quence shown in the figure below.
FIGURE 6. Hall Sensors Sequence
Connection to SSI Absolute Encoder
In Sinusoidal Mode, the controller can use motors equipped with absolute angle sensors
with SSI interface. When enabled, the SSI signals are found on the 6-pin Molex connector
that is otherwise used for the Hall Sensors. The controller issues a clock signal to, and re-
ceives data signals from, the encoder.
FIGURE 7. Hall Sensor Connector Used for SSI Encoders
TABLE 2.
Pin Number 1 2 3 4 5 6
Signal 5V Clock - Clock + Data - Data + Ground
61
6
1